About this item

  • Smartly designed to facilitate easy, clear readings: Paramed blood pressure cuff comes in universal size – 5.3-7.6″ and features a large LCD display to allow for the most accurate readings
  • Do not take measurements after bathing, drinking alcohol, smoking, exercising, or eating. Empty your bladder before measurement.
  • Sit in a chair with your back supported. Do not use devices that emit electromagnetic fields near the unit. Take at least 2 minutes apart, before repeated measurements
  • Take your blood pressure kit anywhere: comes with a durable carrying case in the set. Manual Instruction. Quick Start Guide, 2 AAA batteries included
  • To get accurate measurements, follow the directions in the instructions, quick start guide, and product description page carefully

Product Description

Stay Healthy & Make The Most Of Your Days With Reliable Blood Pressure Measurements

Being healthy is a key ingredient to living a happier life.

Our automatic blood pressure device will give you clear, accurate data by pressing just one button. The large screen makes the use of the monitor more comfortable: it displays the time and date, the measurements themselves, and other icons that simplify the interaction with the device.

We place the trust of our customers first.

We have a very supportive service team. We will answer any of your questions and will solve any problems with the device that may occur.

Rest before measuring

Please rest for at least 10 minutes and take the measurement in a relaxed state. Before you start the measurement, sit comfortably at a table. The feet should rest on the floor, your back straight. Relax and breathe calmly.

Place the device

Put the cuff over your left arm half an inch below your wrist. Fix it firmly with the velcro. Place your elbow on the table, so that the device is on the same level with your heart.

Press the button

Open your palm and turn on the BP monitor. During the measurement, try not to move. Relax, breathe deeply, hold your arm steady and avoid speaking.

 

Get the result

You will learn the measurement results within 45 seconds. It is important not to measure the blood pressure several times in a row without removing the band. The intervals between measurements should be at least 5 minutes.

Frequently Asked Questions

Why do I get results that are too low or too high?

When the body is bent and the sitting position is wrong, it is easy to mistake the product’s cuff to be at the same height as the human heart. Therefore, when the product cuff is higher than the heart, the blood pressure measurement result will be on the low side, and when the product cuff is lower than the heart, the blood pressure measurement result will be on the high side.

Why is it better to measure blood pressure at the same time every day?

The blood pressure value of the human body changes in different periods of the day, so the user thinks that the blood pressure value on the same day should be unchanged, so they think the measurement result is inaccurate.

Why shouldn’t a cuff be worn like a watch?

If wearing the blood pressure monitor like a watch in a wrong way, the signal will be very weak, which resulting in inaccurate blood pressure measurement. The main signal acquisition for product measurement is the cuff, and the cuff must be collected at the inner side of the wrist, because the arterial signal at this position is relatively strong, and then the analog and digital signals can be converted to the MCU to calculate the blood pressure value.

Why is it not recommended to talk during measurements?

The blood pressure measurement technology is the oscillometric method. If you speak or move during the measurement, the cuff and sensor will also detect these interference signals, which will cause the MCU to misread these signals and participate in the algorithm, so the measurement results will be inaccurate.

Factors that may affect the real values of the arterial blood pressure

Сuff is not at the heart level If it is positioned lower than the heart, the measurement result will be higher than normal. Whereas if it is positioned higher than the heart, the measurement result will be lower than normal. These differences can increase/decrease your systolic blood pressure 2mmHg for every inch above/below your heart level.
Back without support Diastolic blood pressure measurement may be increased by 6 mmHg.
Crossing legs Increase systolic blood pressure by 2 to 8 mmHg.
Talking Increase systolic blood pressure by 10 to 15 mmHg.
Not resting 5-10 minutes Increase systolic blood pressure measurement 10 to 20 mmHg.
Full bladder Systolic blood pressure measurements could increase 10 to 15mmHg.
Wear like a watch This is not allowed. Don’t even try.